The CODA-500 is a CODMN monitor that fully automates JIS (Japanese Industrial Standards)-based measurement methods.

  • Uses only 1/10 the reagent of the existing systems

Newly developed dispensing and quantification device enable the CODA-500 to maintain measurement accuracy while using only 1/10 the quantity of reagent required. A reagent delivery service also eliminates the need for time-consuming reagent preparation. This reduces the time and trouble involved in reagent replacement and cuts running costs in half.

  • Touch panel LCD makes operation easier

The use of a color LCD with a touch panel makes operation intuitive, and lowe power consumption reduces environmental load. These and other functions attuned to the times will enable the system to meet future water quality management needs.

  • Cuts power consumption in half
  • Direct heating method requires no cooling water
  • Full range of interface option (RS-232C, RS-485, USB, and Modbus)

Specification

General SpecificationProduct nameAutomatic COD monitor
Model nameCODA-500-A (Acid method) CODA-500-B (Alkaline method)
ObjectCOD concentration in water
Dimensions600 (W) x 510 (D) x 1600 (H) mm
MassApprox. 150 kg
Power source100V-240V AC ± 10% (50/60 Hz)
Power Consumption100V-120V AC: Approx. 250VA 120V-240V AC: Approx. 350VA
Installation conditionsIndoor installation type (connection on sides/no use on back)Transient overvoltage of main power source: overvoltage category II (IEC60334-44), pollution level 2
FunctionMeasurement range0-20 mg/L 0-30, 40, 50, 100, 200, 500, 1000, 2000 mg/L (1-dilution type)
Repeatability (with standard solution for glucose)20 mg/L range : within ± 1% F.S. 30-500mg/L range : within ± 2% F.S. 1000-2000 mg/L range : within ± 5% F.S. 2 point measuring, 2 ranges, and high chloride: within± 5% F.S.
StabilityZero drift and Span drift (for a 24-hour period) 20 mg/L range: within ± 3% F.S. 30-500 mg/L range: within± 4% F.S 1000-2000 mg/L range: within ± 5% F.S.
No. of measurement points1 point (optional 2 points)
Measurement range1 range (optional 2 range)
Heating methodDirect heating
End point detectionPotentionmetric titration at constant current
Titration methodMicro syringe titration
Automatic cleaningSample water reverse cleaning
Measurement period60 Minutes
Cleaning methodReagent cleaning (high-chloride): optional
Silver nitrate solution free methodAvailable (in case of low chloride ion concentration)
Measurement ConditionsAmbient temperature2-40 °C
Ambient humidityRelative humidity: 85% max. (without condensation)
Power supply voltage fluctuations100V-240V AC ± 10%
Sample water conditionsWater temperature2-40 °C (without freezing)
Flow rate (when the overflow tank is used)2-20 L/min
Chloride ion concentration (Acid Potassium Permanganate Method)Standard: Up to 10 times of F.S.Optional (High chloride level type): 10 to 100 times of F.S.(for more than 100 times of F.S., select the alkaline method)
Blank water conditionsWater supplyTap water (standard) Pure water tank (optional)
QualityTap water which contains less COD (hardness: within 100 mg/L)
Water supply pressure100-500 kPa
Consumption20-420 mL (depends on measurement ranges)
Installation conditionWell ventilated indoor location without exposure to direct sunlightFlat and stable location with minimized vibrations and shocksAtmosphere free from dust, mist, corrosive gas, etc.
Input/OutputDisplayLCD color touch panel display
Analog outputNumber of points: 3 points (standard), 6 points (optional)Type: 4-20mA DC, 0-16mA DC (standard)(Default setting is 4-20mA DC. On-screen switching to 0-16mA DC is available)

0-1V DC, 1-5V DC (optional)

Output impedance: 900 Ω or less

Contents: COD, load volume, flow rate

Connection outputNumber of points: 14 points (standard), 21points (optional)Spec: non voltage contact outputType: insulation output

Capacity: 250V AC 3A/30V DC 3A (only contact in maintenance mode)

Analog input2 points (standard), 4 points (optional)Type: 4-20mA DC (standard), 1-5V DC: optionalContent: flow signal (full scale setting is available optionally)
Connection input9 points (standard), 17 points (optional)Spec: Non voltage a contact input (open collector available)Type: insulation input (-)side common

ON resistance: Max. 100 Ω

Open circuit voltage: 26V DC Max.

Short circuit current: 13mA DC Max.

Load calcultaionCOD load calculation
Memory1 year (in measurement value) External USB memory
CommunicationRS-485 (standard) RS-232C (optional)
PrinterStandard (print paper width: 58mm)